Description

  • Temperature limits:
    - 40 ... + 1200° C for type K
    0 ... + 1400° C for type S - R
    +600 ... + 1600° C for type B
    (see table for sheath diameters)
  • Tolerance (IEC standard 584.2/Class 1):
    for type K:
    ± 2.5° C (- 40 ... + 333° C)
    ± 0.0075 x [t] (t > + 333° C)
    for type S, R,
    ± 1° C 0...+1100
    ± [1+0,003 x (t -1100)]°C +1100...+1600°C
    for type B:
    +600° C ... + 1700°C
    ± 0.0025 x [t]
  • Ceramic insulation of the thermocouple element
  • Application versatility

TC9 Ceramic sheath - Steel industry